OVERNIGHT DELIVERY24/7 TECH SUPPORT2 YEAR WARRANTY
- 0 Items
Extend the life of your PLC
Contact Us or Call 1-800-784-9385
The Allen-Bradley / Rockwell Automation 1756-IA16 is a 120V AC ControlLogix Digital Input Module. Operating voltage of 1756IA16 ranges from 74...132V AC, 50/60Hz. 1756-IA16 houses 16 inputs (8 points/group). It has a total backplane power of 0.58W, off-state voltage max. of 20V, on-state current max. of 13mA @ 132V AC, and an inrush current max. of 250mA peak. Removable terminal block housing are the 1756TBNH and 1756TBSH. Isolation voltage of 1756-ia16 is 125V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IA16I is a 120V AC ControlLogix Digital Input Module. Operating voltage of 1756IA16I ranges from 74...132V AC, 50/60Hz. 1756-IA16I houses 16 individually isolated inputs. It has a total backplane power of 0.71W, off-state voltage max. of 20V, on-state current max. of 15mA @132V AC, 47...63Hz and inrush current max. of 250mA. Removable terminal block housing are the 1756-TBCH and 1756-TBS6H. Isolation voltage of 1756-ia16i is 125V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IA32 is a 120V AC ControlLogix Digital Input Module. Operating voltage of 1756IA32 ranges from 74...132V AC, 47...63Hz. 1756-IA32 houses 32 diagnostic inputs (4 points/group). It has a total backplane power of 0.9W, off-state voltage max. of 20V, on-state current max. of 15mA @ 132V AC, and an inrush current max. of 390mA. Removable terminal block housing are the 1756TBCH and 1756TBS6H. Isolation voltage of 1756-ia32 is 250V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IA8D is a 120V AC ControlLogix Digital Input Module. Operating voltage of 1756IA8D ranges from 79...132V AC, 47...63Hz. 1756-IA8D houses 8 diagnostic inputs (4 points/group). It has a total backplane power of 0.58W, off-state voltage max. of 20V, on-state current max. of 16mA @ 132V AC, and an inrush current max. of 250mA peak. Removable terminal block housing are the 1756TBNH and 1756TBSH. Isolation voltage of 1756-ia8d is 125V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IB16 is a 12/24V DC sink ControlLogix Digital Input Module. Operating voltage of 1756IB16 ranges from 10...31.2V DC. 1756-IB16 houses 16 inputs (8 points/group). It has a total backplane power of 0.56W, off-state voltage max. of 5V, on-state current max. of 10mA @ 31.2V DC, and an inrush current max. of 250mA peak. Removable terminal block housing are the 1756TBNH and 1756TBSH. Isolation voltage of 1756-ib16 is 250V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IB16D is a 12/24 V DC sink ControlLogix Digital Input Module. Operating voltage of 1756IB16D ranges from 10...30V DC. 1756-IB16D houses 16 diagnostic inputs (4 points/group). It has a total backplane power of 0.84W, off-state voltage max. of 5V, on-state current max. of 13mA @ 30V AC, and an inrush current max. of 250mA. Removable terminal block housing are the 1756TBCH and 1756TBS6H. Isolation voltage of 1756-ib16d is 250V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IB16I is a 12/24V DC sink/source ControlLogix Digital Input Module. Operating voltage of 1756IB16I ranges from 10...30V DC. 1756-IB16I houses 16 individually isolated inputs. It contains a total backplane power of 0.58W, off-state voltage max. of 5V, on-state current max. of 10mA @ 30V DC, and an inrush current max. of 250mA peak. Removable terminal block housing are the 1756-TBCH and 1756-TBS6H. Isolation voltage of 1756-ib16i is 250V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IB16ISOE is a 24/48V DC sink/source ControlLogix Digital Input Module. Operating voltage of 1756IB16ISOE ranges from 10...55V DC. 1756-IB16ISOE houses 16 individually isolated inputs, sequence of events inputs. It contains a total backplane power of 1.7W, off-state voltage max. of 5V, and an on-state current max. of 5.1mA @ 48...55V DC. Removable terminal block housing are the 1756-TBCH and 1756-TBS6H. Isolation voltage of 1756-ib16isoe is 250V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IB32 is a 12/24V DC sink digital input module. Operating voltage of 1756IB32 ranges from 10...31.2V DC. This input module houses 32 inputs (16 points/group). Removable terminal block houses 1756-TBCH and 1756-TBS6H. 
The Allen-Bradley / Rockwell Automation 1756-IC16 is a 48V DC sink ControlLogix Digital Input Module. Operating voltage of 1756IC16 ranges from 30...55V DC or 30...60V DC. 1756-IC16 houses 16 inputs (8 points/group). It contains a total backplane power of 0.58W, off-state voltage max. of 10V, on-state current max. of 7mA @ 60V DC, and an inrush current max. of 250mA. Removable terminal block housing are the 1756-TBNH and 1756-TBSH. Isolation voltage of 1756-ic16 is 250V (continuous).
The Allen-Bradley / Rockwell Automation 1756-IG16 is a 5V DC TTL source (Low=True) Digital Input Module. It houses 16 inputs (8 points/group). Operating Voltage range of 1756IG16 is 4.5...5.5V DC. Removable Terminal block houses 1756-TBNH and 1756-TBSH.
The Allen-Bradley / Rockwell Automation 1756-IH16I is a 125V DC sink/source digital input module. It houses 16 individually isolated inputs. Operating voltage range of 1756IH16I is 90...146V DC. Removable terminal block houses 1756-TBCH and 1756-TBS6H.
The Allen-Bradley / Rockwell Automation 1756-IH16ISOE is a 125V DC sink/source digital input module. It houses 16 individually isolated inputs. Operating voltage range of 1756IH16ISOE is 90...140V DC. Removable terminal houses 1756-TBCH and 1756-TBS6H.
The Allen-Bradley / Rockwell Automation 1756-IM16I is a 240V AC digital input module. It houses 16 individually isolated inputs. Operating voltage range of 1756IM16I is 159...265V AC. Removable terminal houses 1756-TBCH and 1756-TBS6H.
The Allen-Bradley / Rockwell Automation 1756-IN16 is a 24V AC digital input module. It houses 16 inputs (8 points/group). Operating voltage range of 1756IN16 is 10...30V AC. Removable terminal houses 1756-TBNH and 1756-TBSH.
The Allen-Bradley / Rockwell Automation 1756-IV16 is a ControlLogix 12/24V DC source digital input module. It houses 16 inputs (8points/group). Operating voltage range of 1756IV16 is 10...30V DC. Removable terminal block houses 1756-TBNH and 1756-TBSH.
The Allen-Bradley / Rockwell Automation 1756-IV32 is a ControlLogix 12/24V DC source digital input module. It houses 32 inputs (8 points/group). Operating voltage range of 1756IV32 is 10...30V DC. Removable terminal block houses 1756-TBCH and 1756-TBS6H.
The Allen-Bradley / Rockwell Automation 1756-OA16 is a 120/240V AC digital output module. It houses 16 mechanically fused/group outputs (8 points/group). Operating voltage range for 1756OA16 is 74...265V AC. Removable terminal block houses 1756-TBNH and 1756-TBSH.
The Allen-Bradley / Rockwell Automation 1756-OA16I is a 120/240V AC digital output module. It houses 16 individually isolated outputs. Operating voltage range for 1756OA16I is 74...265V AC. Removable terminal block houses 1756-TBCH and 1756-TBS6H.
The Allen-Bradley / Rockwell Automation 1756-OA8 is a 120/240V AC digital output module. It houses 8 outputs (4 points/group). Operating voltage range for 1756OA8 is 79...265V AC. Removable terminal block houses 1756-TBNH and 1756-TBSH.