Repair GE-Emerson IC693MDL330 120/240 Volt and 2 Amp AC Output Module
Provides 8 output points in two isolated groups with four points per group.
Remanufactured
-
5 in stock
For on-site repair and support, call us at 1-704-448-2212 or email sales@qualitrol.com.
- IC693MDL330REP
- By GE-Emerson
Overview
Features
- 120/240VAC rated voltage
- 85 to 264VAC, 50/60Hz output voltage range
- Isolation:
- 1,500V between field side and logic side
- 500V between each group
- Output current:
- 2 Amp max. per point
- 4 Amp max. per group at 104°F
- Output characteristics:
- 20 Amp max. inrush current for one cycle
- 100mA minimum load current
- 1.5V max. output voltage drop
- Output leakage current:
- 3mA max. at 120VAC
- 5mA max. at 240VAC
- 1ms max. On response time
- 1/2 cycle max. Off response time
- 160mA power consumption (all outputs on) from 5V bus on backplane
Description
The GGE-Emerson IC693MDL330 120/240 Volt and 2 Amp AC Output Module includes a separate common associated with each group. The two commons are not tied together inside the module. This allows each group to be used on different phases of the AC supply, or they can be powered from the same supply. Each group is protected with a 5 amp fuse for each common, and an RC snubber is provided for each output to protect against transient electrical noise on the power line. This module provides a high-degree of inrush current (10x the rated current) which makes the outputs suitable for controlling a wide range of inductive and incandescent loads. AC Power (DC power cannot be used) to operate loads connected to outputs must be supplied by the user.
LED indicators that provide the ON/OFF status of each point are located at the top of the module. There are two horizontal rows with eight green LEDs in each row and a red LED centered between and to the right of the two rows. This module uses the upper eight LEDs, labeled A1 through 8 for output status. The red “F” LED is a blown fuse indicator that turns ON if any of the fuses should blow. An insert goes between the inside and outside surface of the hinged door. The surface towards the inside of the module (when the hinged door is closed) has circuit wiring information, and circuit identification information can be recorded on the outside surface. The outside left edge of the insert is color-coded red to indicate a high-voltage module. This module can be installed in any I/O slot of a 5 or 10-slot baseplate in a Series 90-30 PLC system.