Repair Allen-Bradley 1771-IGD PLC-5 TTL Input Module
16 inputs per module.
Remanufactured
-
1 in stock
- 1771-IGDREP
Overview
Features
- Input voltage rating:
- HIGH = TRUE
- ON: 2.0 to 5.25VDC
- OFF: -0.2 to +0.8VDC
- LOW = TRUE
- ON: -0.2 to +0.8VDC
- OFF: 2.0 to 5.25VDC
- HIGH = TRUE
- Customer current sink requirements:
- 7mA max. (source per input)
- 0.8mA max. (sink per input)
- Customer supply voltage:
- 5.0VDC (+/-0.25V) class 2
- 50mV peak-to-peak ripple max.
- 380mA max. customer supply current per module
- <1ms input signal delay
- 0.4 to 2.7W power dissipation
- 1.4 to 9.2 BTU/hr thermal dissipation
- 5VDC, 130mA max. backplane voltage/current
- Tested to 600VDC for 1s isolation voltage
- Open-style enclosure
Description
The Allen-Bradley 1771-IGD PLC-5 TTL Input Module can be used in a Series A or B 1771-A1B, -A2B, -A3B, -A3B1, and -A4B chassis. The module is also compatible in a 1771-AM1 or -AM2 I/O chassis.
The operator can use any TTL device that meets the output logic level specification of -0.2VDC to +0.8VDC (low), and 2.0VDC to 5.25VDC (high).
The module contains input filtering to limit the effects of voltage transients caused by contact bounce and/or radiated electrical noise. The delay due to filtering is less than 1ms.
For maximum noise immunity, the output of the TTL device should have a pull-up resistor of 1Kohm (typical). Add an external pull-up resistor to the output terminals of the device, if necessary. If a pull-up resistor is added, the TTL device should maintain the low state requirement of -0.2VDC to +0.8VDC with the increased load.