Repair

Call for pricing
  • Usually ships in 3-5 business days

Remanufactured

Call for pricing
  • 4 in stock
  • IC692MDR541REP

Overview

Features

  • Input specifications:
    • Points per common: 12 (I5-I16) and 4 (I1-I4; includes 2 High Speed Counter inputs)
    • 24VDC rated input voltage
    • 0 to 30VDC input voltage range
    • 7.3mA typical input current
    • Input threshold voltage:
      • ON: 15V min.
      • OFF: 5V max.
    • Input threshold current:
      • ON: 4mA max.
      • OFF: 1.5mA min.
    • 4ms typical response time
    • Isolation voltage:
      • 1500V RMS field side to logic side
      • 1500V RMS between each group if one group is powered by an external 24V power supply
  • Output specifications:
    • Operating voltage:
      • 5 to 30VDC
      • 5 to 250VAC
    • 11 outputs per module (three groups: one with 3 outputs, two with 4 outputs)
    • 1500V RMS isolation
    • 1mA at 240VAC max. leakage current
    • 2 Amps resistive max. load per output
    • 10mA min. load
    • 20 Amps max. inrush for one cycle
    • 15ms max. ON or OFF response time

Description

The GE-Emerson IC692MDR541 Series 90-20 DC Input/Relay Output Power Supply provides input circuits designed to have positive or negative logic characteristics. To connect the inputs as positive logic circuits, the input switching device is connected between the positive power bus and the module input. The negative bus is connected to the input circuit common. To connect the inputs as negative logic circuits, the input switching device is connected between the negative power bus and the module input. The positive bus is connected to the input circuit common. Current into an input point results in a logic 1 in the input status table (%I).

Input characteristics are compatible with a wide range of input devices, such as: pushbuttons, limit switches, and electronic proximity switches. 

The 2 Amp relay output circuits provide 11 normally-open relay circuits for controlling output loads provided by the user. The output switching capacity of each of these circuits is 2 Amps. The output points are arranged in three groups; one with three outputs and two with four outputs. Each group has a common power output terminal. The relay outputs can control a wide range of user-supplied load devices, such as: motor starters, solenoids, and indicators. Power for the internal relay circuits is provided by the +5VDC internal supply. The user must supply the AC or DC power to operate field devices. Each common has a 10 Amp replaceable fuse.